Minimum Requirements Prior to Occupancy Permit Being Issued (for Single Family Structures)
Updated: October 2023
- All required inspections must be completed.
- Certificate of Installation of On-Site Septic System.
- If applicable, at least one (1) entry door to have landings, steps, handrails, and guards installed to code (National Building Code, 2015 or current edition).
- All interior lofts, stairs, and landings to have handrails and guards installed to code (National Building Code, 2015 or current edition), this also includes basement stairs.
- Air Exchanger to be installed and functioning as well as a Mechanical Ventilation Record to be submitted to this office.
- Plumbing vent to be through roof and of proper size.
- All required smoke alarms/ carbon monoxide alarms to be installed and functioning.
- Shut off valve on all toilets.
- Single key dead bolts installed on all exterior doors.
- Attached garages which have a common wall and/or ceiling shall be gyproced (or other appropriate materials) with joints sealed. Entry door between garage and dwelling shall be made airtight and have a self closing device installed.
- The hot water tank or boiler vessel shall be equipped with the applicable pressure/temperature relief valve. This valve shall be equipped with a pipe to direct exhausted steam within 12 inches of floor level.
- All heating and/or cooling equipment to be installed in accordance with the manufacturer’s instructions or in the absence of instructions, the applicable standard.
- An attic hatch, if applicable, shall be air tight.
- All flue pipe connections shall be secured with a minimum of three sheet metal screws per joint.
- A kitchen sink with hot and cold water, and one (1) toilet and bathtub or shower operational. Also, a door is required on the bathroom with floor covering. NOTE: Trim, kitchen cupboards, or other non essential doors are not required.
- Any additional requirements as may be required by the Building Inspector; please refer to the National Building Code, current edition and its regulations.
- Reflective civic number posted.
- Exterior siding complete.
Please note, these are guidelines only. Depending on the type of construction there may be additional requirements.
Prior to an occupancy permit being issued. The Municipality of the District of Lunenburg does not guarantee this list to be exhaustive or all inclusive. Every construction remains/is subject to the regulations of the current edition of the National Building Code. Please call 902-541-1325 for additional information.